Legal capacity monitoring
Count every guest.
Prove it to the inspector.
CapacityIQ counts people at the door with a ceiling sensor that captures no images, warns the door staff before the authorised limit and keeps the log the fire inspectorate asks for. Since 13 March 2026 every club, bar and disco in Romania must do exactly that.
The obligation
What the law requires from bars, clubs and discos
Romania made permanent counting mandatory on 13 March 2026 (Legea 307/2006, art. 19 (1) r5, as amended by OUG 17/2026). Germany treats the permitted number as a binding ceiling above 200 visitors. France sets capacity at four persons per three square metres and leaves the counting to the operator.
| Requirement in the law | How CapacityIQ meets it |
|---|---|
| Respect the authorised maximum number of users | Live occupancy counter with the venue's authorised capacity as the hard limit; changes are logged. |
| Permanent monitoring and counting by mechanical equipment or an automatic electronic system | Time-of-flight sensor counts bi-directionally 24/7, up to 99.8 % accuracy; local storage keeps counting through network outages. |
| Equipment must not narrow the escape routes | Ceiling-mounted above the door, 200 × 85 × 35 mm. No gates, turnstiles or floor hardware. |
| One or more persons responsible for access | Door-staff view with count, places left and colour state; the responsible person signs on per shift. |
| Evidence for an inspection | Daily compliance report: occupancy curve, peak, breaches, responsible person. Export to PDF or CSV. |
Legal references: Legea 307/2006, art. 19 (1) r5, art. 45 (1) IV d, art. 47, as amended by OUG 17/2026; Normativ P118/1-2025, definition 73. This page is not legal advice.
What it does
One sensor above the door. Compliance every night.
Time-of-flight depth sensing: up to 99.8 % counting accuracy, works at 0 lux, no camera images.
Live occupancy
Entries, exits and net occupancy in real time, per entrance and for the whole venue.
Capacity guard
The authorised maximum is the hard limit. Green, amber, red states; alerts at 85 % and at the limit.
Door-staff view
Tablet or phone at the door: current count, places left, who is the responsible person on shift.
Compliance log
Every count, breach and reset stored on device and in the cloud. One-click export for a control.
Works in the dark
Invisible 940 nm light. Strobes, fog and darkness do not affect the count.
No images, GDPR-safe
Depth map only. No faces, no video, nothing to sign, nothing to store.
Multi-entrance
Up to 8 sensors stitched into one count. Terrace doors included.
Staff excluded
Staff wearing a lanyard are not counted as guests.
Normal entry.
Alert to the responsible person and the manager. Slow the door.
Stop entry. Optional relay to a door light. Breach logged if exceeded.
The application
What the manager sees the morning after
Every night is one report: the occupancy curve against the authorised limit, the peak, the time above 85 %, the responsible person on duty and every alert in the order it happened.
What the responsible person sees all night
- 1
One number, one colour
Guests inside now, places left, and a green, amber or red state. Readable at arm's length in a dark doorway, on any phone or a wall tablet.
- 2
Amber at 85 %, red at the limit
The door slows before the limit, not after. Alerts also go by SMS or push to the manager, and optionally to a door light through the sensor's alarm output.
- 3
Signed-on responsible person
The law requires a named person responsible for access. The app records who signed on, when, and at which door, and puts it in the report.
- 4
Pause entry and log
One tap pauses entry and stamps the log. Reopening is logged too. Nothing is edited by hand, so the record holds up in a control.
- 5
Multiple doors, one count
Every door counts into the same venue total. Door staff at each entrance see the same number.
Why time-of-flight
Built for club conditions
CapacityIQ time-of-flight sensor
- ✓Works at 0 lux; strobes and fog do not matter
- ✓Depth map only, no images captured or stored
- ✓Up to 99.8 % bi-directional accuracy, U-turn filtering
- ✓One PoE cable, ceiling above the door, no calibration
- ✓Counting log on the device itself, shown to the inspector
Counting on existing CCTV
- !Accuracy drops in low light and with lighting effects
- !Images of guests: DPIA, signage, retention rules
- !Accuracy depends on camera angle; side-by-side entries are missed
- !Cameras rarely look straight down at the door
- !Hard to prove counting accuracy during a control
Sensor specification
Time-of-flight people counter, two mounting variants
| Parameter | Standard | High ceiling |
|---|---|---|
| Technology | 2nd-generation time-of-flight + AI, 940 nm invisible light | same |
| Installation height | ≤ 3.5 m | 2 to 6.5 m |
| Counting area | 4.14 × 3.02 m at 3.5 m | 5.54 × 3.98 m at 6.5 m |
| Counting accuracy | up to 99.8 % | up to 99.8 % |
| Counting lines | up to 4, bi-directional, U-turn filtering | same |
| Zones and dwell time | up to 4 zones | same |
| Staff detection | lanyard | lanyard |
| Children / adults | yes | yes |
| Multi-sensor stitching | up to 8 sensors (PoE) | up to 8 sensors (PoE) |
| Connectivity | Ethernet PoE; LTE and LoRaWAN variants | same |
| Protocols | HTTP(S), MQTT(S), CGI, BACnet/IP, 802.1x | same |
| Alarm output | 1 in / 1 out (PoE version) | 1 in / 1 out (PoE version) |
| Local storage | 1 million records, CSV export, retransmission | same |
| Power | PoE+ (802.3at) or 12 V DC, avg 8 W | PoE+ or 12 V DC, avg 10 W |
| Environment | −20 to 50 °C, IP40 | −20 to 50 °C, IP40 |
| Size, weight, colour | 200 × 35 × 85 mm, 419 g, white or black | same |
| Certification | CE, GDPR | CE, GDPR |
Manufacturer's stated specifications. Counting area is the detection area.
From a single door to a concert hall
| Venue | Door width | Sensors | Notes |
|---|---|---|---|
| Bar, one door, ceiling ≤ 3.5 m | ≤ 2.5 m | 1 × standard | Entry level |
| Club, main entrance, ceiling ≤ 3.5 m | ≤ 4 m | 1 × standard | Alarm output to a door light |
| Club, wide or high entrance | 4 to 8 m | 2 × standard, stitched | One combined count |
| Multi-entrance venue with terrace | any | 1 sensor per door, stitched | Terrace door counted too |
| Hall, ceiling 4 to 6.5 m | ≤ 3 m per sensor | high ceiling | Concert venues, event halls |
Installation: one PoE cable to the ceiling above the door, typically under two hours per sensor, no works on the floor or in the escape route. Remote-assisted self-install available.
How it goes
From the law to the first compliant night
1. The obligation
Bars, clubs and discos must count guests since 13 March 2026. Fine up to 10,000 lei.
now2. Get in touch
The form below, or our partner in Romania.
2 min3. Venue assessment
Send a floor plan, a photo of each door and your authorised capacity.
10 min4. Design and quote
Sensors, placement, one fixed price.
2 business days5. Installation
One cable above each door. Nothing on the escape route.
under 2 h per door6. Test night
Count checked, alerts set, door staff onboarded.
1 night7. Go live
Your first compliant night.
same night8. Done. Run your business.
A report every night, one click for a control.
ongoing Plus insightsWhen your nights peak, how long, and what an event brings.Ready to start? Send us three things.
You get a fixed quote within two business days.
Request a quote- A floor plan of the venue. A sketch or the plan from your ISU file is enough.
- A photo of each entrance from inside, showing the door and the ceiling above it.
- Your authorised capacity, as it appears on the ISU permit.
Included: Traffic Analytics
The same sensor runs the business, not only the door
Every CapacityIQ subscription includes the Pygmalios Traffic Analytics module.
Visits and occupancy
Guests by hour, night and weekday, occupancy curve of every night, peak times and how long they last.
Conversion with your POS
Match visits with receipts to get buying units and conversion per night, per event and per bar.
Events and promotions
Compare a DJ night, a promotion or a new opening hour against normal nights, weather-adjusted.
Staffing to demand
See when the door, the bar and the floor are actually busy, and plan shifts and security to it.
Reports that explain why
Regular contextualised reports combine your traffic with weather, local events and market context, delivered as a branded PDF.
Dashboard, exports, API
Web dashboard for every venue, CSV exports, REST API and MQTT feed for your own systems, multi-venue comparison for chains.
Questions
Frequently asked
Does the law apply to a small bar?
Yes. Art. 19 (1) r5 names clubs, bars and discos without a size threshold. The 200-person threshold applies to the separate category of crowded halls.
Do I need a camera?
No. The sensor measures distance and produces a depth map. It captures no images and stores none.
What happens when the network drops?
The sensor keeps counting and stores up to one million records locally, then retransmits.
Can I count several doors as one venue?
Yes, up to 8 sensors are stitched into one count.
What do I show during a control?
The daily compliance report: occupancy curve, peak, breaches, and who was the responsible person. PDF or CSV.
Who installs it?
Our partner or your electrician: one PoE cable to the ceiling above the door, typically under two hours per sensor. Remote-assisted self-install is available.
Next step
Send us a floor plan, a photo of each door and your authorised capacity.
You get a fixed quote within two business days.
Download the datasheet (PDF) →Request a quote