Legal capacity monitoring

Count every guest.
Prove it to the inspector.

CapacityIQ counts people at the door with a ceiling sensor that captures no images, warns the door staff before the authorised limit and keeps the log the fire inspectorate asks for. Since 13 March 2026 every club, bar and disco in Romania must do exactly that.

The obligation

What the law requires from bars, clubs and discos

Romania made permanent counting mandatory on 13 March 2026 (Legea 307/2006, art. 19 (1) r5, as amended by OUG 17/2026). Germany treats the permitted number as a binding ceiling above 200 visitors. France sets capacity at four persons per three square metres and leaves the counting to the operator.

13 Mar 2026
In force
OUG 17/2026, Monitorul Oficial I nr. 199
5,000–10,000 lei
Fine per breach
art. 45 (1) IV d, in force since 12 April 2026
0
Warnings
art. 47 (7): the fine applies directly
What the law requires from bars, clubs and discos
Requirement in the law How CapacityIQ meets it
Respect the authorised maximum number of users Live occupancy counter with the venue's authorised capacity as the hard limit; changes are logged.
Permanent monitoring and counting by mechanical equipment or an automatic electronic system Time-of-flight sensor counts bi-directionally 24/7, up to 99.8 % accuracy; local storage keeps counting through network outages.
Equipment must not narrow the escape routes Ceiling-mounted above the door, 200 × 85 × 35 mm. No gates, turnstiles or floor hardware.
One or more persons responsible for access Door-staff view with count, places left and colour state; the responsible person signs on per shift.
Evidence for an inspection Daily compliance report: occupancy curve, peak, breaches, responsible person. Export to PDF or CSV.
Chart of legal capacity thresholds for venues in Romania, Germany and France

Legal references: Legea 307/2006, art. 19 (1) r5, art. 45 (1) IV d, art. 47, as amended by OUG 17/2026; Normativ P118/1-2025, definition 73. This page is not legal advice.

What it does

One sensor above the door. Compliance every night.

Time-of-flight depth sensing: up to 99.8 % counting accuracy, works at 0 lux, no camera images.

Live occupancy

Entries, exits and net occupancy in real time, per entrance and for the whole venue.

Capacity guard

The authorised maximum is the hard limit. Green, amber, red states; alerts at 85 % and at the limit.

Door-staff view

Tablet or phone at the door: current count, places left, who is the responsible person on shift.

Compliance log

Every count, breach and reset stored on device and in the cloud. One-click export for a control.

Works in the dark

Invisible 940 nm light. Strobes, fog and darkness do not affect the count.

No images, GDPR-safe

Depth map only. No faces, no video, nothing to sign, nothing to store.

Multi-entrance

Up to 8 sensors stitched into one count. Terrace doors included.

Staff excluded

Staff wearing a lanyard are not counted as guests.

Green · below 85 %

Normal entry.

Amber · 85 to 100 %

Alert to the responsible person and the manager. Slow the door.

Red · at the limit

Stop entry. Optional relay to a door light. Breach logged if exceeded.

Diagram of a ceiling sensor above a doorway with its counting area and the 85 % and 100 % thresholds

The application

What the manager sees the morning after

Every night is one report: the occupancy curve against the authorised limit, the peak, the time above 85 %, the responsible person on duty and every alert in the order it happened.

CapacityIQ manager dashboard with the occupancy curve of one night against the authorised limit
Phone screen at the door showing the current count, places left and a green state

What the responsible person sees all night

  1. 1

    One number, one colour

    Guests inside now, places left, and a green, amber or red state. Readable at arm's length in a dark doorway, on any phone or a wall tablet.

  2. 2

    Amber at 85 %, red at the limit

    The door slows before the limit, not after. Alerts also go by SMS or push to the manager, and optionally to a door light through the sensor's alarm output.

  3. 3

    Signed-on responsible person

    The law requires a named person responsible for access. The app records who signed on, when, and at which door, and puts it in the report.

  4. 4

    Pause entry and log

    One tap pauses entry and stamps the log. Reopening is logged too. Nothing is edited by hand, so the record holds up in a control.

  5. 5

    Multiple doors, one count

    Every door counts into the same venue total. Door staff at each entrance see the same number.

Why time-of-flight

Built for club conditions

CapacityIQ time-of-flight sensor

  • Works at 0 lux; strobes and fog do not matter
  • Depth map only, no images captured or stored
  • Up to 99.8 % bi-directional accuracy, U-turn filtering
  • One PoE cable, ceiling above the door, no calibration
  • Counting log on the device itself, shown to the inspector

Counting on existing CCTV

  • !Accuracy drops in low light and with lighting effects
  • !Images of guests: DPIA, signage, retention rules
  • !Accuracy depends on camera angle; side-by-side entries are missed
  • !Cameras rarely look straight down at the door
  • !Hard to prove counting accuracy during a control
A camera view of a dark club entrance next to the depth map a ceiling sensor sees

Sensor specification

Time-of-flight people counter, two mounting variants

Time-of-flight people counter, two mounting variants
Parameter Standard High ceiling
Technology 2nd-generation time-of-flight + AI, 940 nm invisible light same
Installation height ≤ 3.5 m 2 to 6.5 m
Counting area 4.14 × 3.02 m at 3.5 m 5.54 × 3.98 m at 6.5 m
Counting accuracy up to 99.8 % up to 99.8 %
Counting lines up to 4, bi-directional, U-turn filtering same
Zones and dwell time up to 4 zones same
Staff detection lanyard lanyard
Children / adults yes yes
Multi-sensor stitching up to 8 sensors (PoE) up to 8 sensors (PoE)
Connectivity Ethernet PoE; LTE and LoRaWAN variants same
Protocols HTTP(S), MQTT(S), CGI, BACnet/IP, 802.1x same
Alarm output 1 in / 1 out (PoE version) 1 in / 1 out (PoE version)
Local storage 1 million records, CSV export, retransmission same
Power PoE+ (802.3at) or 12 V DC, avg 8 W PoE+ or 12 V DC, avg 10 W
Environment −20 to 50 °C, IP40 −20 to 50 °C, IP40
Size, weight, colour 200 × 35 × 85 mm, 419 g, white or black same
Certification CE, GDPR CE, GDPR

Manufacturer's stated specifications. Counting area is the detection area.

From a single door to a concert hall

From a single door to a concert hall
Venue Door width Sensors Notes
Bar, one door, ceiling ≤ 3.5 m ≤ 2.5 m 1 × standard Entry level
Club, main entrance, ceiling ≤ 3.5 m ≤ 4 m 1 × standard Alarm output to a door light
Club, wide or high entrance 4 to 8 m 2 × standard, stitched One combined count
Multi-entrance venue with terrace any 1 sensor per door, stitched Terrace door counted too
Hall, ceiling 4 to 6.5 m ≤ 3 m per sensor high ceiling Concert venues, event halls

Installation: one PoE cable to the ceiling above the door, typically under two hours per sensor, no works on the floor or in the escape route. Remote-assisted self-install available.

How it goes

From the law to the first compliant night

You are here

1. The obligation

Bars, clubs and discos must count guests since 13 March 2026. Fine up to 10,000 lei.

now

2. Get in touch

The form below, or our partner in Romania.

2 min

3. Venue assessment

Send a floor plan, a photo of each door and your authorised capacity.

10 min

4. Design and quote

Sensors, placement, one fixed price.

2 business days

5. Installation

One cable above each door. Nothing on the escape route.

under 2 h per door

6. Test night

Count checked, alerts set, door staff onboarded.

1 night

7. Go live

Your first compliant night.

same night

8. Done. Run your business.

A report every night, one click for a control.

ongoing Plus insightsWhen your nights peak, how long, and what an event brings.
YouPygmaliosTogetherDone
12 min of your time before the quote
2 business days to a fixed price
1 afternoon from installation to the first compliant night

Ready to start? Send us three things.

You get a fixed quote within two business days.

Request a quote
  1. A floor plan of the venue. A sketch or the plan from your ISU file is enough.
  2. A photo of each entrance from inside, showing the door and the ceiling above it.
  3. Your authorised capacity, as it appears on the ISU permit.

Included: Traffic Analytics

The same sensor runs the business, not only the door

Every CapacityIQ subscription includes the Pygmalios Traffic Analytics module.

Visits and occupancy

Guests by hour, night and weekday, occupancy curve of every night, peak times and how long they last.

Conversion with your POS

Match visits with receipts to get buying units and conversion per night, per event and per bar.

Events and promotions

Compare a DJ night, a promotion or a new opening hour against normal nights, weather-adjusted.

Staffing to demand

See when the door, the bar and the floor are actually busy, and plan shifts and security to it.

Reports that explain why

Regular contextualised reports combine your traffic with weather, local events and market context, delivered as a branded PDF.

Dashboard, exports, API

Web dashboard for every venue, CSV exports, REST API and MQTT feed for your own systems, multi-venue comparison for chains.

Diagram of one night in a club: occupancy by hour with the door, bar and floor peaks marked

Questions

Frequently asked

Does the law apply to a small bar?

Yes. Art. 19 (1) r5 names clubs, bars and discos without a size threshold. The 200-person threshold applies to the separate category of crowded halls.

Do I need a camera?

No. The sensor measures distance and produces a depth map. It captures no images and stores none.

What happens when the network drops?

The sensor keeps counting and stores up to one million records locally, then retransmits.

Can I count several doors as one venue?

Yes, up to 8 sensors are stitched into one count.

What do I show during a control?

The daily compliance report: occupancy curve, peak, breaches, and who was the responsible person. PDF or CSV.

Who installs it?

Our partner or your electrician: one PoE cable to the ceiling above the door, typically under two hours per sensor. Remote-assisted self-install is available.

Next step

Send us a floor plan, a photo of each door and your authorised capacity.

You get a fixed quote within two business days.

Download the datasheet (PDF) →

Request a quote

Proven in production

DM Drogerie Markt
“Long-term observations through Pygmalios Analytics can provide us with a comprehensive picture of the best-selling product groups, and we can also visually detect changes in buying behavior based on external incentives.”
Lubomír Franta

Lubomír Franta

CIO, DM Drogerie Markt

2,000+
locations live
250M+
sessions analyzed
20+